Medical dry laser cameras have been widely used in hospitals, it completely replaced the traditional halide photosensitive material in the imaging process of developing a certain shadow washing dry 1000 program, but to obtain data directly from medical imaging equipment, by laser printing on film and developing imaging directly after the heating of the heating drum, but also multi-machine network share a camera. Our hospital since 2000 have introduced KODAK Dry view 8700,8200, CT, CR, digital gastrointestinal machine printed film over 20,000 pictures are clear. Especially the low power laser pointer  is very practical.
Dry-type structure and working principle of laser camera KODAK Dry view dry-type laser camera for the film cartridge, transfer roller, laser head, the exposure cabin, heated drum, as well as automatic image quality control components such as composition, and the KODAK PACS LINK server and DICOM network connection. KODAK Dry view Dry Laser camera workflow: the machine is first open for the film box, self-performance testing and heated imaging drum warm-up, when the print start ① sucker will film sucked out, ② ③ reach the laser exposure through the transfer roller area exposure ④ The re-transmission roller, ⑤ the heating drum heating developing imaging ⑥ Finally, the image quality control system output film (Figure 1). The green laser pointer is well received in the current market. 
Closed treatment for the cassette, cut off the power, open the top cover or door card bit, found along the transmission line of the film, clear film, re-print. Note to clear the heating drum around card, not to touch the high temperature of the heated drum surface so as not to burn. CR system and the 8100 camera down so the analysis and overhaul of medical imaging equipment is constantly updated, CR, DR, and digital photography equipment gradually put hospitals and used in the clinical examination. Hospital in December 2004, the introduction of the U.S. Kodak CR850 scanning system, configure the 8100 laser printer. In the course of some of the failure and repair analysis process, although not complicated, but very practical value. Is introduced to the peer for reference. The provider also should give some useful suggestion about laser pointer to the customer.It is the security knowledge of laser pointer 
Carefully to find the mouse within the scanning system was removed he used the mouse plug in the fault disappears. This failure is purely human error, but so that the repair process of the maintenance engineers unknowingly detours.

No comments:

Post a Comment